<?xml version='1.0' encoding='UTF-8'?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Apadana</PublisherName>
      <PublisherNameVernacular>موسسه آموزش عالی آپادانا</PublisherNameVernacular>
      <JournalTitle>Biannual Journal Novel Interdisciplinary Legal Research</JournalTitle>
      <JournalTitleVernacular>فصلنامه پیشرفت های مهندسی در حوزه پزشکی و مواد</JournalTitleVernacular>
      <Issn>-</Issn>
      <Volume>2</Volume>
      <Issue>2</Issue>
      <PubDate PubStatus="epublish">
        <Year>2026</Year>
        <Month>08</Month>
        <Day>11</Day>
      </PubDate>
    </Journal>

    <ArticleTitle>Clinical Applications of Static Posturography for Balance Assessment and Rehabilitation: Introducing Best Balance™, a Novel Iranian Force Plate System</ArticleTitle>
    <VernacularTitle>کاربردهای بالینی پاسچروگرافی ایستا در ارزیابی و بازتوانی تعادل: معرفی سامانه صفحه نیروی «بست بالانس» ساخت ایران</VernacularTitle>

    <FirstPage>50</FirstPage>
    <LastPage>66</LastPage>
    <ELocationID EIdType="doi"></ELocationID>
    <Language>FA</Language>

    <AuthorList>
      <Author>
        <FirstName>mahdi</FirstName>
        <LastName>shojaei</LastName>
        <Affiliation>Mahdi Shojaei, B.Sc. in Electrical Engineering, CEO of Ariana Mechatronics Researchers, Qazvin, I</Affiliation>
        <VernacularFirstName>مهدی</VernacularFirstName>
        <VernacularLastName>شجاعی</VernacularLastName>
        <VernacularAffiliation>مهدی شجاعی، کارشناس مهندسی برق، مدیرعامل شرکت پژوهشگران مکاترونیک آریانا، قزوین، ایران</VernacularAffiliation>
      </Author>
      <Author>
        <FirstName>mohamadreza</FirstName>
        <LastName>shojaei</LastName>
        <Affiliation>Mohammadreza Shojaei, B.Sc. in Mechanical Engineering, CTO, Ariana Mechatronics Researchers, Qazvin, Iran</Affiliation>
        <VernacularFirstName>محمدرضا</VernacularFirstName>
        <VernacularLastName>شجاعی</VernacularLastName>
        <VernacularAffiliation>محمدرضا شجاعی، کارشناس مهندسی مکانیک، مدیر فنی، شرکت پژوهشگران مکاترونیک آریانا، قزوین، ایران</VernacularAffiliation>
      </Author>
      <Author>
        <FirstName>zahra</FirstName>
        <LastName>rehyani nezhad</LastName>
        <Affiliation>Specialized Corrective Exercise Clinic, Red Crescent society of the Islamic republic of Iran, Tehran, Iran.</Affiliation>
        <VernacularFirstName>زهرا</VernacularFirstName>
        <VernacularLastName>ریحانی نژاد</VernacularLastName>
        <VernacularAffiliation>کلینیک تخصصی حرکات اصلاحی، مرکز جامع توان بخشی، جمعیت هلال احمر جمهوری اسلامی ایران، تهران، ایران</VernacularAffiliation>
      </Author>
      <Author>
        <FirstName>majed</FirstName>
        <LastName>dehghani</LastName>
        <Affiliation>Department of Medical Sciences and Technologies, ST.C., Islamic Azad University, Red Crescent society of the Islamic republic of Iran,  Tehran, Iran</Affiliation>
        <VernacularFirstName>ماجد</VernacularFirstName>
        <VernacularLastName>دهقانی</VernacularLastName>
        <VernacularAffiliation>گروه علوم و فناوری های پزشکی، واحد تهران جنوب، دانشگاه آزاد اسلامی،جمعیت هلال احمر جمهوری اسلامی ایران، تهران، ایران</VernacularAffiliation>
      </Author>
    </AuthorList>

    <PublicationType></PublicationType>

    <History>
      <PubDate PubStatus="received">
        <Year>2026</Year>
        <Month>08</Month>
        <Day>05</Day>
      </PubDate>
    </History>

    <Abstract>Static postural control arises from continuous interaction among the visual, vestibular, and proprioceptive sensory systems. Traditional clinical balance assessments have been limited by examiner-dependent judgment and low sensitivity to subtle changes, while existing commercial static posturography systems have largely relied on imported technology and foreign technical support. This study aimed to provide a technical description of the Best Balance static force plate system and to conduct a narrative-comparative review of its clinical applications across different patient populations. Following a descriptive-analytical approach, the study was conducted in two parts: first, the hardware architecture, signal-processing algorithm, and evaluation protocols of the Best Balance system (manufactured by Ariyana Mechatronic Researchers, 2021) were examined by administering a clinical sensory interaction balance test and a postural stability test to one healthy adult volunteer as a proof-of-concept demonstration; second, a narrative literature search was conducted using keywords related to posturography, center of pressure, and interactive rehabilitation, and technical specifications of comparable commercial systems were extracted. Data analysis involved extraction of kinematic indices from center-of-pressure time series. The Best Balance system reliably tracked center-of-pressure displacement across different sensory conditions, reflecting a progressive increase in postural sway consistent with reduced sensory input availability. The postural stability test revealed directional asymmetries in voluntary center-of-pressure control, and the system generated structured clinical reports. The Best Balance system was introduced as a domestically developed static posturography technology with quantitative assessment and interactive rehabilitation capabilities. Further clinical validation studies and establishment of normative data for the Iranian population are recommended.</Abstract>
    <OtherAbstract Language="FA">کنترل قامت ایستا از تعامل پیوسته سیستم های حسی بینایی، دهلیزی و حس عمقی حاصل می شود و ارزیابی بالینی سنتی آن با محدودیت هایی نظیر وابستگی به قضاوت آزمونگر و حساسیت پایین در تشخیص تغییرات جزئی همراه بوده است؛ در مقابل، دستگاه های پاسچروگرافی ایستای تجاری موجود عمدتاً وارداتی و وابسته به پشتیبانی خارجی بوده اند. هدف این مطالعه، معرفی فنی سامانه صفحه نیروی ایستای «بست بالانس» و مرور روایی-مقایسه ای کاربردهای بالینی پاسچروگرافی ایستا بود. پژوهش توسعه ای-کاربردی با رویکرد توصیفی-تحلیلی در دو بخش انجام شد: نخست، معماری سخت افزاری، الگوریتم پردازش سیگنال و پروتکل های ارزیابی سامانه بست بالانس (ساخت شرکت دانش بنیان پژوهشگران مکاترونیک آریانا، ۱۴۰۰) با اجرای آزمون تعامل حسی بالینی و آزمون پایداری قامتی بر داوطلب سالم بزرگسال، انتخاب شده به شیوه نمونه گیری در دسترس، به عنوان اثبات مفهوم بررسی شد؛ دوم، جست وجوی روایی متون با کلیدواژه های مرتبط با پاسچروگرافی، مرکز فشار و توانبخشی تعاملی انجام و مشخصات فنی سامانه های تجاری مشابه استخراج گردید. تحلیل داده ها با استخراج شاخص های سینماتیک سری زمانی مرکز فشار انجام شد. یافته ها نشان داد سامانه بست بالانس قادر به ثبت پایدار جابه جایی مرکز فشار در شرایط مختلف حسی است و الگوی افزایش تدریجی نوسان قامتی متناسب با کاهش ورودی های حسی در دسترس را بازتاب می دهد؛ همچنین آزمون پایداری قامتی الگوهای عدم تقارن جهتی در کنترل ارادی مرکز فشار را آشکار ساخت و سامانه قادر به تولید گزارش های بالینی ساختارمند بود. سامانه بست بالانس به عنوان فناوری بومی پاسچروگرافی ایستا با قابلیت های ارزیابی کمّی و توانبخشی تعاملی معرفی شد و انجام مطالعات اعتبارسنجی بالینی با جمعیت های بیمار برای تعمیم پذیری بیشتر یافته ها پیشنهاد گردید.</OtherAbstract>

    <ObjectList>
      <Object Type="keyword"><Param Name="value">Static Posturography</Param></Object>
      <Object Type="keyword"><Param Name="value">Force Plate</Param></Object>
      <Object Type="keyword"><Param Name="value">Center of Pressure (CoP)</Param></Object>
      <Object Type="keyword"><Param Name="value">Postural Control</Param></Object>
      <Object Type="keyword"><Param Name="value">Balance Assessment</Param></Object>
      <Object Type="keyword"><Param Name="value">Rehabilitation</Param></Object>
      <Object Type="keyword"><Param Name="value_vernacular">اسچروگرافی ایستا</Param></Object>
      <Object Type="keyword"><Param Name="value_vernacular">صفحه نیرو</Param></Object>
      <Object Type="keyword"><Param Name="value_vernacular">مرکز فشار</Param></Object>
      <Object Type="keyword"><Param Name="value_vernacular">کنترل قامتی</Param></Object>
      <Object Type="keyword"><Param Name="value_vernacular">ارزیابی تعادل</Param></Object>
      <Object Type="keyword"><Param Name="value_vernacular">بازتوانی</Param></Object>
    </ObjectList>

    <ArchiveCopySource DocType="pdf">https://ram.apadana.ac.ir/downloadfilepdf/345115</ArchiveCopySource>
  </Article>
</ArticleSet>